Aeration System - Piping System 1Piping System1). Arrangement of air header pipeFrom blower to aeration tank, pipe length = 100 ft, D = 18 ", V= 3,300 fpM Distribution Header D = 18", Length = 62 ft Branch of Air Header d = 12", Length = 96 ft 2). Total friction head loss from blower to last branch headerFind hbranch/100 ft from Chart CFM-D-Temperature-Gauge Pressure-H(CFM-D-T-P-H chart) T �F = 9/5 �25�C + 32 � 80 �F Gauge pressure > 6.5 (depth)+ 0.1(Swig aerator) + 0.3(diffuser)� 7 Psi Select gauge pressure of blower � 8 Psi Branch Header: H12" = hbranch � L = 0.28"/100 � 96 = 0.27" Division header, d = 16" For Q = 3,550 CFM H14" = 0.66" � 0.31 = 0.20" (H2O) For Qair = 3 � 1,775 CFM = 5,325 CFM H14" = 0.65"/100 � 31 = 0.20" (H2O) Main Header , Q = 10,226,440/24 � 60 = 7,100 CFM H18" = 0.64"/100 � 100 = 0.64" Total head loss Ht = 0.64 + 0.20 + 0.20 + 0.27 = 1.31" � 0.05 Psi | Previous Page | Main Page | Next Page|
|